<LOGO>
FM Transmitter Measurement Report
Created: 2024-04-20 01-56-57
Measuring equipment: P75/P175/P275
http://pira.cz
Station Details
Frequency Signal Reception Station Name
100.20 MHz 4/5, 36 dBuV INTER
Pilot RDS Phase Difference
7.2 kHz 3.0 kHz -51 deg
Frequency Deviation
Limit Measuring Tolerance
75,0 kHz 0,0 kHz
MIN Hold Max. Samples at Total Samples % above 75,0 kHz
20 kHz 27 kHz 3797 0,0263
Modulation Power
Limit Measuring Tolerance
10,0 dBr 0,2 dBr
MIN AVE MAX % above 10,2 dBr
1,7 dBr 2,95 dBr 4,9 dBr 0,0
Radio Data System
PS PI PTY TP TA  MS   DI   CT 
" INTER " F201 0 (No PTY) 1 0 1 1 1:56, 20.04.2024
RT
"FRANCE INTER PREMIERE RADIO DE FRANC "
AF EON
92.6, 94.6, 94.9, 99.2, 99.9, 100.2 MHz F202, F206, F203, F209
FM Scope Station: 100.20 MHz, signal: 4/5 (36 dBuV) Max at: 27 kHz MIN: 20 kHz % above 75 kHz: 0,0263 Acquired: 2024/04/20 1:55:54 Total samples: 3797 Equivalent time: 0:03:09 0 10 20 30 40 50 60 70 80 90 100 110 120 Frequency Deviation [kHz] 0 50 100 150
FM Scope MAX: 4,9 dBr MIN: 1,7 dBr AVE: 2,95 dBr % above 10,2 dBr: 0,0 Last value: 2,1 dBr (2024/04/20 1:55:54) Station: 100.20 MHz, signal: 4/5 (36 dBuV) 01:44 01:46 01:48 01:50 01:52 01:54 0 50 100 Dev. MAX [kHz] 0 2 4 Pm [dBr] 0 5 Signal Quality